Water Treatment System Replacement Parts

Water Replacement PartsWhy Replacement Parts Matter for Industrial-Grade Water Systems

For facilities relying on high-purity water (labs, manufacturing, electronics, power plants, etc.), the performance of water treatment systems is only as good as their maintenance over time. With repeated use, membranes clog, ion-exchange modules lose effectiveness, and power supplies or control components can degrade.

Using proper, high-quality replacement parts ensures sustained water quality, prevents system failures, reduces downtime, improves safety, and keeps maintenance costs predictable. Skimping on parts — or letting them wear out — can lead to contamination, reduced water purity, or more frequent rebuilds. Routines for replacing parts are integral for efficiency and long-term reliability. Read on to learn how to identify when your equipment parts require replacement and explore expert recommendations for best practices and maintenance.

 

When & Why to Replace Parts

Declining water quality: If your water no longer meets purity specs, it’s often a sign that RO membranes or EDI stacks are exhausted or fouled
Lower flow rate / pressure drop: Membrane fouling or scaling will gradually reduce throughput; replacing RO membranes can restore flow
Routine maintenance schedule: Many systems follow preventive maintenance cycles. For example, ion-exchange membranes (in some contexts) are replaced every 18–36 months once their ion-selectivity degrades beyond acceptable limits
Upgrading capacity or specs: If your water demand increases or purity requirements become stricter, you might replace standard membranes/modules with higher-grade ones
Electrical or control failures / modernization: Aging power supplies, sensors, or control panels can compromise EDI performance; replacing with updated control hardware ensures stable, efficient operation

 

Best Practices for Replacement & Maintenance

Match part specifications exactly: Because modules are engineered to specific flow rates, pressures, and purity specs, you must use correct model replacements rather than “generic” parts
Use OEM or trusted-brand parts: When possible, rely on recognized suppliers/manufacturers to ensure compatibility and longevity
Follow pretreatment & system design requirements: For EDI modules especially, proper pretreatment (e.g. RO first, pretreatment filtration/softening) protects the membranes and extends their life
Maintain power/control components: EDI stacks need stable, correctly rated DC power supplies — neglecting these can degrade performance even if membranes are fresh
Establish a maintenance schedule & log performance: Track water quality metrics and system throughput; when metrics drift, that’s your cue it’s time for replacement

 

Quality Replacement parts from UCC Environmental

Electrodeionization IONPURE Replacement Parts

Ionpure MX Modules

Ionpure MX Series CEDI modules are a “round disc” EDI. The MX delivers superior performance for laboratory and lower flow process applications. MX modules are an ideal complement for light industrial, commercial & laboratory RO systems that are wall mounted or housed in a cabinet.

 

Ionpure LX Modules

The Ionpure LX modules are specifically designed for industrial applications. Ionpure modules consistently deliver maximum reliability and superior performance for power, HPI/CPI, general electronics, food and beverage and laboratory applications without regeneration downtime. The Ionpure LX EDI modules are nominally rated between 2 and 15 gpm per module.

 

Ionpure VNX Modules

The VNX module uses a “round disc” design to reduce the cost of building high flow rate EDI systems and to make it easy to choose a clean, environmentally compatible technology over chemically regenerated mixed bed ion exchange systems. Higher flowrate EDI modules result in easier piping and system assembly by reducing the number of modules required.

Model #Nominal Flowrate (gpm)Minimum Flow Rate (gpm)Maximum Flow Rate (gpm)Description
IP-LXM04Z-5213LX-Z04 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LXM10Z-552.57.5LX-Z10 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LXM18Z-594.513.5LX-Z18 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LXM24Z-512.56.318.75LX-Z24 Module (General Industry, w/ 0.05ppm Cl tolerance))
IP-LXM30Z-5157.522.5LX-Z30 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LXM45Z-522.511.333.75LX-Z45 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LX8000Z-535.217.652.8LX-Z8000 Module (General Industry, w/ 0.05ppm Cl tolerance)
IP-LXM4X-4213LX-X04 Module (NSF 14; NSF61)
IP-LXM10X-452.57.5LX-X10 Module (NSF 14; NSF61)
IP-LXM18X-494.513.5LX-X18 Module (NSF 14; NSF61)
IP-LXM24X-412.56.318.75LX-X24 Module (NSF 14; NSF61)
IP-LXM30X-4157.522.5LX-X30 Module (NSF 14; NSF61)
IP-LXM45X-422.511.333.75LX-X45 Module (NSF 14; NSF61)
IP-LXM4HI-3213LX-HI04 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM10HI-352.57.5LX-HI10 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM18HI-394.513.5LX-HI18 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM24HI-312.56.318.75LX-HI24 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM30HI-3157.522.5LX-HI30 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM45HI-322.511.333.75LX-HI45 Module HWS (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM4EU-4213LX-EU04 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM10EU-452.57.5LX-EU10 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM18EU-494.513.5LX-EU18 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM24EU-412.56.318.75LX-EU24 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM30EU-4157.522.5LX-EU30 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LXM45EU-422.511.333.75LX-EU45 Module (FDA 21CFR177, NSF 51, NSF 61 & EU 90/128/EEC)
IP-LX04 RB213LX04 (X or Z) Module Rebuild
IP-LXM10 RB52.57.5LX10 (X or Z) Module Rebuild
IP-LXM18 RB94.513.5LX18 (X or Z) Module Rebuild
IP-LXM24 RB12.56.318.75LX24 (X or Z) Module Rebuild
IP-LXM30 RB157.522.5LX30 (X or Z) Module Rebuild
IP-LXM45 RB22.511.333.75LX45 (X or Z) Module Rebuild
IP-LXM04HRB213LX04 HI Module Rebuild, Hot Water Sanitizable
IP-LXM10HRB52.57.5LX10 HI Module Rebuild, Hot Water Sanitizable
IP-LXM18HRB94.513.5LX18 HI Module Rebuild, Hot Water Sanitizable
IP-LXM24HRB12.56.318.75LX24 HI Module Rebuild, Hot Water Sanitizable
IP-LXM30HRB157.522.5LX30 HI Module Rebuild, Hot Water Sanitizable
IP-LXM45HRB22.511.333.75LX45 HI Module Rebuild, Hot Water Sanitizable
IP-LXM04EURB213LX04 EU Module Rebuild
IP-LXM10EURB52.57.5LX10 EU Module Rebuild
IP-LXM18EURB94.513.5LX18 EU Module Rebuild
IP-LXM24EURB12.56.318.75LX24 EU Module Rebuild
IP-LXM30EURB157.522.5LX30 EU Module Rebuild
IP-LXM45EURB22.511.333.75LX45 EU Module Rebuild
IP-VNX-MAX-1P663399VNX-MAX (w/ DC3 Power Controller)
IP-VNX-MAX-1663399VNX-Max (Module Only)
IP-VNX-MINI-1P52.826.479.2VNX-Mini Housing (w/ DC3 Power Controller)
IP-VNX-MINI-152.826.479.2VNX-Mini 168 cm Housing (Module Only)
IP-VNX28EP-227.513.841.25VNX28 Enhanced Performance
IP-VNX55E-25527.582.5VNX-E (High recovery Micro-E)
IP-VNX55EP-25527.582.5VNX-EP (Enhanced Performance)
IP-VNX55EX-25527.582.5VNX-EX (High performance Micro-E)
IP-VNX55ULTRA-25527.582.5VNX-ULTRA (Ultra performance Micro-E)
IP-VNX55HH-2442266VNX-HH (High Hardness)
IP-VNX30CDIT-2301545VNX30-CDIT (High Hardness, High Silica)
IP-VNX15CDIT-2157.522.5VNX15-CDIT (High Hardness, High Silica)
IP-MXM030-20.140.10.21MX30 Module
IP-MXM060-20.280.10.42MX60 Module
IP-MXM125-20.550.30.825MX125 Module
IP-MXM250-21.10.61.65MX250 Module
IP-MXM500-22.21.13.3MX500 Module
Model Description
IP-DC3PH600V1-M1DC3 Power Supply3-Phase DC Power Supply, 0-600V, 0-15A DC
IP-POWER-G4-M*NEW* G4 Power Controller1-Phase DC Power Supply, 0-600V, 13.2A, MODBUS
IP-POWER-G4-R1-Phase DC Power Controller, 0-600V, 0-13.2A Replacement for G2 and PCB Power Controllers
IP-DCR600V15A-MDCR Power ControllersDC RECTIFIER, 600VDC 15A DIN Rail mountable with MODBUS communication
IP-DCR600V15A-R2RETROFIT DC RECTIFIER, 600VDC 15A w/ 0-5VDC communication Replacement for G2 and PCB power controllers
IP-RCSHUNT-DCRRC Shunt Circuit for DCRRC Shunt Circuit for DCR controllers with a shared secondary. This part is INCLUDED with new DCR power controllers.
IP-POWERDSP-TPTouch Panel Display4.3" Touch Panel Display for DCR-M, DC3, G4 Includes RJ45 to DB9 adapter for DCR-M
IP-POWER600-G2Discontinued: Consider
G4R as a replacement. New installations use DC3 or G4
G2 - 600VDC 13.2Amp Power Controller,CE/UL/RoHS
IP-POWERDSP-G2G2 -Display Board, CE/RoHS
(for use with G2 and DCR-R2 Power controllers)

 

Iontech EDI Modules

Iontech EDI modules are DS series CEDI stacks and industrial grade. The Iontech modules produce ultrapure water with no chemical regeneration. Iontech EDI is a highly reliable type of water treatment equipment Product quality as measured in MΩ -cm generally exceeds mixed bed quality as well as other EDI technologies.

Iontech EDI ModuleNominal Flow Rating (gpm)Minimum Flow (gpm)Maximum Flow (gpm)Operating Current (ADC)Operating Voltage (VDC)Operating Weight (lbs)
IT-DS052130-6 0-30 100
IT-DS1052.570-60-60155
IT-DS2094.5130-60-135175
IT-DS2412.56.5180-60-165200
IT-DS30157.5220-60-200275
IT-DS5022.411.5330-60-300325

 

EDI Power Supplies

UCC provides power supply control panels for Electrodeionization modules. The DC Power Controllers are designed to be used with all Electrodeionization modules for optimal performance.

ModelNumber of EDI ModulesMax Current & Volts per Module (ADC)Max Current & Volts per Module (vdc)Transformer KVAIncoming Current (Amps AC) 220VIncoming Current (Amps AC) 380VIncoming Current (Amps AC) 480VPanel Dimensions H (in)Panel Dimensions W (in)Panel Dimensions D (in)Est. Ship_x0002_Weight (lbs)
1MX12.5200, 400, OR 6003.515101030301275
2MX12.5200, 400, OR 6007302020363016100
1 LX26.5200 OR 4004.5251515303012125
2LX26.5200 OR 40092530363016220
1LX or IVNX2516.56006.5302020303012175
2LX or 2VNX2526.560013.24030363016250
1VNX113.2600124530303016175
2VNX213.2600246060483620325
3VNX313.2600367575723024550
4VNX413.260048100100723024750
6VNX613.2600721501207248241000
8VNX813.2600961751607248241500

 

E-Cell Electrodeionization (EDI) Water Treatment

SUEZ’s E-Cell electrodeionization (EDI) technology removes residual salts and ionizable aqueous species – such as carbon dioxide, silica, ammonia and boron – from your water sources. The EDI systems operate chemical-free, achieve 97% water recovery, and consume only electricity. They are ideal for multiple applications including: power generation for boiler feed and NOx control, semiconductors, microelectronics, food and beverage, and pharmaceuticals.

Model
MK1
MK2E
MK-3
MK-3X
MK-3PharmaHT
MK-3MiniHTPharma
MK-7

 

Reverse Osmosis Membrane Replacement Parts

LG Water Solutions, a division of LG Chem, manufactures NanoH2O™ seawater and brackish water reverse osmosis (RO) membrane elements based on the breakthrough Thin-Film Nanocomposite (TFN) technology.

LG Water Solution’s NanoH2O™ brackish water RO membranes are gaining traction with major utilities and industrial end-users worldwide. The TFN technology, coupled with intrinsic anti-fouling properties, delivers reliable performance and reduced operational downtime, leading to a lower total cost of plant ownership.

Seawater RO Membranes
Low EnergyLG SW 400 ES
LG SW 440 ES
High RejectionLG SW 400 SR G2
LG SW 440 SR G2
LG SW 400 GR G2
LG SW 440 GR G2
LG SW 400 R G2
LG SW 440 R G2
LG SW 400 SR
LG SW 440 SR
LG SW 400 GR
LG SW 440 GR
LG SW 400 R
LG SW 440 R
LG SW 4040 R
Brackish Water RO Membranes
Ultra-Low Energy*LG BW 4040 UES*
LG CW 4040 SF*
LG BW MOST
LG BW MOST+
Low Energy**LG BW 400 ES
LG BW 440 ES
LG BW 400 ES L
LG BW 440 ES L
LG BW 4040 ES**
High RejectionLG BW 400 R G2
LG BW 440 R G2
LG BW MaxRO
LG BW 400 R Dura
LG BW 440 R Dura
LG BW 400 R
LG BW 440 R
LG BW 4040 R***
LG BW 400 AFR G2
LG BW 400 AFR
Commercial RO Membranes
High Rejection*LG BW 2521 R
LG BW 2540 R
LG BW 4021 R
Low Energy*LG BW 2521 ES
LG BW 2540 ES
LG BW 4021 ES
Ultra-Low Energy*LG BW 2521 UES
LG BW 2540 UES
LG BW 4021 UES

 

Conclusion

For facilities depending on high purity water, investing in high-quality replacement parts isn’t optional — it’s essential. Whether it’s swapping RO membranes for sustained filtration, replacing EDI modules for consistent deionization, or maintaining power/control hardware, having a robust replacement-and-maintenance program protects water quality, ensures reliability, and reduces long-term costs and surprises.

> Learn more about Water Treatment Solutions

> Contact Us

Comments are closed.